F R E Q U E N T L Y A S K E D Q U E S T I O N S
|
|
|
|
Why is the tubing 8î apart?
|
TOP
|
Close spacing provides the best comfort. Tubing spaced further apart can create hot/cold spots, especially with low R-value finished floor goods. Closer spacing also provides better performance. |
|
How much does it cost to install TB?
|
TOP
|
An inexperienced crew of two able carpenters can install an average of 150 sq. ft. per hour. |
|
When is Thermal Track™ installed?
|
TOP
|
Thermal Track™ is typically installed just prior to the installation of finished flooring goods. Store Thermal Track™ on the job site in a dry, cool space and it is ready to be installed with delays, in the natural progression of construction. |
|
May I attach Thermal Track™ directly to concrete?
|
TOP
|
NO. Thermal Track™ is specifically designed for attachment to a subfloor (plywood or OSB). If Thermal Track™ is used over concrete, the installer must employ a vapor barrier and securely attach ž plywood or OSB to the concrete prior to application of the Thermal Track™. A separate Thermal Track™ product for direct application to concrete will be introduced in late 2004. |
|
May I nail hardwood directly to Thermal Track™?
|
TOP
|
Yes, this is great advantage of Thermal Track™. You must use hardwood nails long enough to secure Thermal Track™ to the sub floor (see the Thermal Track™ Application/Installation manual). |
|
Should I attach something to TB before applying carpet?
|
TOP
|
We recommend a minimum 1/8î plywood or Masonite sheet be applied over Thermal Track™ to avoid the remote possibility of extreme point load damage (kids with jack knives). |
|
May I glue flooring goods to TB?
|
TOP
|
No. The WarmCoat aluminum surface is attached to the board with non-VOC glue that does not provide a ñstructuralî connection. |
|
May I install a mortar bed over TB?
|
TOP
|
Yes. When installed with a slip-sheet or
approved crack isolation membrane and proper reinforcement mesh, hard
pack mortar may be applied over TK.
|
|
Will a tubing leak destroy Thermal Track™?
|
TOP
|
Leaks sometimes occur during construction, primarily due to conflicting trades. Prolonged exposure to moisture will result in Thermal Track™ swelling. The leak should be immediately repaired. Immediate drying of the area will usually avoid any damage to Thermal Track™. |
|
How do I design manifold locations?
|
TOP
|
As you would normally. Tubing approaching a manifold location can be accommodated in custom grooves (with a standard 5/8î router) or covered with mortar. |